When you need to replace an existing surface mounted door closer the easiest way is to match the bolt hole pattern up this will allow you to install your new closer in the same place as the old one.
Door closer size chart.
Minimum additional considerations number 6 14 lbs.
The size ratings are from 1 to 6 with size 1 the weakest strength and size 6 the strongest.
Fire doors within en 1154 certain recommendations are made for closing devices used on fire door assemblies.
Allen key adjust door closer strength as per chart on template.
Choosing a direct fit replacement door closer.
Size 3 5 pounds of closing force minimum.
Each closer manufacturer has their own selection chart that will help you select the right size based on the height and weight of your door.
Door closerscross reference 8 tc300 400 61 951 na na s40 na ev66 500 dc51 tc2200 700 90 680 780 850 880 980 750 8050 s225 255 d 1550 s52 s55 s70 530 950 dx50 dx90 600 dc52 5 tc200 na na na na s50 s51 na na na na tc400 801 5050 na d 3551 na bf900 70 na pr50 tc500 8015 5000 na d 3550 na 900bc 70 na pr52 tc600 900 9000 na na s2500 na na 1900 na.
Door closers shall not include a.
Size 1 2 pounds of closing force minimum.
Chart credit bernards.
There are two styles of door closers.
Drill pilot holes in door and frame according to template.
The most widely used setting is size 3 and the standard adjustable closer will be set at a size 3 when shipped.
Minimum there are some applications that may require a special type of closer such as a hold open feature positive or spring stop.
Choosing the correct door closing hardware involves more than just picking something from the hardware store shelf.
They are visible economical and the easiest to install.
Closers size 1 and 2 are not considered suitable for use on fire doors.
Common are a size 4 for an external 36 inch wide commercial door and a size 3 for an internal commercial or residential application.
How to choose the correct door closer.
Closers which are controlled by an electromagnetic function must comply with the additional requirements of en 1155.
Door closer reference guide.
Consider the door type construction and.
Surface mounted closers are installed on the surface of the door and frame.
Selecting the correct door closer to suit door size this product is non handed and can be fitted on both left handed and right handed doors.
Minimum number 4 8 lbs.
Architectural commercial norton corbin russwin sargent lcn arrow yale dorma pdq cal royal stanley falcon hager 9500 dc8000 281 4040xp x x x x x x x x 7500 dc6000 1431 351 4040xp x 4400 8900 x x d4550 sc70 x 8501 dc3000 1331 1460 72fc 5016n 3501 8600 5500 x d3551 x x 8301 dc3000 1331 1460 72 5016n 3301 8600 5300 x d3550.
Size 2 3 pounds of closing force minimum.
Minimum number 3 5 lbs.
Minimum number 5 11 lbs.
Minimum size for use on fire doors.
Minimum number 2 3 lbs.
Door closers are rated by opening closing force size.